EvacPath Team15 May 2026Updated 9 October 202612 min read
On this page16 sections
  1. How inspectors actually assess diagrams
  2. 1. The "You Are Here" marker is wrong
  3. 2. The diagram is a generic template, not site-accurate
  4. 3. The diagram orientation is wrong
  5. 4. The diagram is mounted too high or too low
  6. 5. The diagram has no validity date, or the validity date has passed
  7. 6. The diagram is smaller than the AS 3745 minimum size
  8. 7. A mandatory element is missing
  9. 8. A fit-out or renovation completed without re-issuing the diagram
  10. 9. The diagram is faded, damaged, or obscured
  11. 10. The assembly area shown no longer exists or is inaccessible
  12. 11. The diagram is mounted on a fire door
  13. 12. Missing diagrams at required locations
  14. Audit-window readiness checklist
  15. When to engage a supplier for re-issue rather than touch-ups
  16. Get inspection-ready diagrams

Most evacuation diagram audit failures in Australia are not exotic technical defects. They are the same handful of mistakes, made over and over, by building owners and managers who inherited a stale set of diagrams or commissioned them from a template-overlay supplier years ago. Every fire safety practitioner who signs an Annual Fire Safety Statement, every council inspector running an occupancy check, every Fire and Rescue officer responding to a complaint walks in with the same short list of things they check first.

This post lists the 12 most common reasons an evacuation diagram fails an AS 3745 audit, with the clause reference, why the inspector flags it, and the fix. Each item is something the building owner can audit themselves, on a single walk-through, before an inspection lands.

For the broader inspection context (who conducts inspections, what they cover beyond diagrams, what happens when deficiencies are issued), the companion post is what happens during a fire safety inspection. For the full standard, evacuation diagram requirements: AS 3745 Australia guide covers every mandatory and optional element.

How inspectors actually assess diagrams

Before the list, a quick note on the inspector mindset. Inspectors are not looking for theoretical perfection. They are looking for whether the diagram, mounted in this location, in this state of currency, in this lighting, would actually help an occupant evacuate. That is the single mental model they apply. Everything else (the clause numbers, the size minimums, the orientation rules) is the standardised way of asking that question.

When you do your own audit walk-through, stand in front of each diagram and ask: if this building filled with smoke right now, would this diagram tell me what to do, where to go, who to call, and what to look for on the way? The mistakes below all break that test.

1. The "You Are Here" marker is wrong

This is the single most common failure. Someone moved the diagram, or copied a diagram from one location to another, and the "You Are Here" marker now points to the wrong spot. An occupant standing at the entrance, looking at a diagram that says "You Are Here" near the back hallway, will misread every exit route on the page.

AS 3745:2010 is explicit: the pictorial representation of the building must include the location of the diagram itself, accurately. Inspectors check this by physically standing where the diagram is mounted, looking at the marker, and verifying it matches.

Fix: every diagram must be rendered for its specific mounting location. The same building floor needs multiple diagrams, each with its own "You Are Here" indicator. A single diagram copied to ten locations fails ten ways. If you are commissioning diagrams, ask the supplier how many "You Are Here" variants will be produced. The answer should match the number of mount locations.

2. The diagram is a generic template, not site-accurate

Template-overlay diagrams are the second most common failure. A supplier takes a stock floor plan that approximates the tenancy, adds your business name and contact numbers, and prints it. The exit routes are inferred, not measured. Fire equipment locations are placed where they "usually" are. Manual call points are shown in plausible positions, not actual ones.

Inspectors detect this in two ways. The first is visual: a real floor plan has the asymmetries and quirks of a real building (an offset doorway, an unusual column placement, a non-rectangular meeting room). Template overlays look too clean. The second is verification: an inspector walks the building and finds a fire extinguisher marked on the diagram that is not actually mounted on that wall, or a manual call point in the diagram that does not exist on the ground.

Fix: the diagram must be drawn from your actual floor plan (architectural plans, tenancy plan, or a measured-up survey), with fire equipment locations verified on site. If your existing diagrams look like a generic template, replace them before the next inspection. The emergency evacuation diagrams buyer's guide covers how to spot template-overlay suppliers before commissioning.

3. The diagram orientation is wrong

AS 3745:2010 clause 3.5.4 requires that the diagram be oriented from the viewer's perspective. If the diagram is mounted on a north-facing wall, "up" on the diagram must correspond to whatever the viewer would see by walking straight forward from the diagram. North-up is not a default. Viewer-relative orientation is mandatory.

A common audit failure: a single diagram artwork is reproduced at four mount locations around a building, all rotated the same way (typically north-up). At three of those locations, the diagram is misoriented relative to the viewer, and an occupant trying to find the nearest exit will instinctively go the wrong direction.

Fix: each diagram must be rendered with its own orientation, matched to the mount location. The same floor in a building can need 4, 6, or 8 different diagram orientations, one per mount point. This is why a serious supplier produces a separate render per location, not a single artwork.

4. The diagram is mounted too high or too low

AS 3745:2010 clause 3.5.3 sets the position. In FPA Australia's summary of it (Information Bulletin IB-11), the diagram should hang with either its bottom edge no lower than 1,200 mm above the floor or its top edge no higher than 1,600 mm. Those are two alternative tests, not a band the whole sheet must fit inside: a diagram at standing height uses the bottom-edge test, and a lower, accessible diagram uses the top-edge test. The aim behind both is to keep the floor plan near eye level. Mounted too low, a diagram is blocked by furniture and not seen; mounted too high, it sits above the eye line and the floor plan detail becomes hard to read in an emergency.

Inspectors carry a tape measure. They will spot-check 2 or 3 diagrams in a building. A diagram hung up over a doorway for "visibility" passes the bottom-edge test on paper, but nobody can read its floor plan from the floor, so expect it to be flagged as unreadable.

Fix: install diagrams at 1,500 mm to the centre as a safe target. On an A4 or A3 sheet, either way up, that keeps the bottom edge above 1,200 mm. For accessible mounting (where wheelchair users are the primary audience, such as NDIS facilities or aged care), mount lower, with the centre around 1,200 mm to 1,300 mm (on an A4 or A3 sheet the top edge then stays under 1,600 mm). Never hang a diagram up near the ceiling or over a doorway even if the wall geometry tempts it. The evacuation diagram printing and installation guide covers mounting hardware and placement detail.

5. The diagram has no validity date, or the validity date has passed

AS 3745:2010 clause 3.5.5(l) requires a validity date on the diagram, and FPA Australia guidance recommends showing a date of issue alongside it. The reason is simple: an undated diagram cannot be assessed for currency. An inspector looking at a diagram without a date does not know whether the building has been renovated since, whether the fire equipment locations are still accurate, or whether the contact numbers were last verified a decade ago.

The validity period is nominated by the Emergency Planning Committee (clause 2.2(d)), and FPA Australia guidance says it should not exceed 5 years, though it may be shorter. A diagram dated 2017 in a building inspected in 2026 is presumed invalid unless evidence of a validation pass is produced.

Fix: every diagram must show a clear validity date, ideally with a date of issue alongside it, in a font size legible at the mounted height. Re-issue before the validity date lapses (5 years at the most), and re-issue immediately after any renovation, tenancy change, or change to fire equipment locations. How often should evacuation diagrams be updated covers the cadence in detail.

6. The diagram is smaller than the AS 3745 minimum size

AS 3745:2010 clause 3.5.7 specifies size minimums. With only mandatory elements, the diagram must be at least A4 (210 x 297 mm) overall, with the floor plan graphic at least 200 x 150 mm (30,000 mm2). If optional elements are included (emergency numbers, first aid kits, AEDs, disabled refuge areas, fire and smoke doors, hydrants), the minimum size increases to A3 (297 x 420 mm), with the floor plan graphic at least 300 x 200 mm (60,000 mm2).

A common failure: a building that needs disabled refuge or AED locations shown (which most modern commercial buildings do) is still using A4 diagrams. The inspector measures the floor plan graphic, finds it under 60,000 mm2, and flags the diagram as undersized.

Fix: default to A3 for any building with optional elements (almost all multi-tenant or larger commercial buildings). Use A4 only when the diagram carries the mandatory elements alone (typically a single small tenancy with no emergency numbers, first aid, AED, disabled refuge or hydrants shown). Warden intercommunication points, where a building has them, are communications equipment, a mandatory element, so they go on the diagram at either size. Evacuation diagram size: AS 3745 requirements explained details every measurement.

7. A mandatory element is missing

AS 3745:2010 clause 3.5.5 lists the mandatory elements. In FPA Australia's summary (Information Bulletin IB-11) they include the designated exits and the green paths of travel to them, communications equipment, the fire indicator panel, manual and emergency call points, first-attack firefighting equipment, the "You Are Here" point and the location of the facility, plus a validity date and a legend, all drawn on a floor plan of the area. Warden intercommunication points count as communications equipment, so they belong on the diagram wherever a building has them. The assembly area belongs on the diagram too. Missing any one of these is a fail. Emergency contact numbers are not on that list: clause 3.5.6 makes them optional, and showing them raises the minimum size to A3 (item 6).

The two most common omissions in the field: manual call points (the small red "break glass" panels for activating the fire alarm) and the assembly area. Manual call points get missed because they are easy to overlook during the floor walk for the diagram artist. Assembly areas get missed because some buildings genuinely have a poorly-defined assembly area and the diagram author chose to omit it rather than guess.

Fix: cross-check every new diagram against the AS 3745 mandatory element list before sign-off. The evacuation diagram requirements: AS 3745 Australia guide lists each element. The diagram should show every fire extinguisher, hose reel, fire blanket, manual call point, emergency call point, warden intercommunication point (where installed), the fire indicator panel, every exit sign, and the assembly area, with the assembly area location precisely defined on the diagram or on a block plan attachment. Hydrants are optional (clause 3.5.6), so show them where your emergency plan includes them; showing them makes A3 the minimum (item 6).

8. A fit-out or renovation completed without re-issuing the diagram

This is the silent failure mode. A tenant moves a wall, adds a meeting room, converts a storage cupboard into a server room, or relocates a fire extinguisher to a different bracket. None of those events trigger an automatic re-issue of the diagram. Six months later, the diagram on the wall no longer matches the layout the inspector walks through, and the entire diagram is invalid.

AS 3745:2010 requires the diagram to stay current: it must be re-issued whenever the layout, exit routes, or fire equipment locations change. The validity date printed on the diagram (5 years out at the most) is a backstop, not a substitute. Any material change to the building during the validity window triggers an immediate re-issue.

Fix: bake the diagram re-issue into the fit-out close-out checklist. Every fit-out, every tenancy change, every internal wall move, every fire equipment relocation should trigger a diagram update before the work is signed off. Tenant fit-out evacuation diagram requirements covers the close-out process. The supplier should be on the close-out call so updates can be commissioned the same week the fit-out completes.

9. The diagram is faded, damaged, or obscured

AS 3745:2010 implicitly requires that the diagram be legible (the standard would be meaningless otherwise). In practice, inspectors flag diagrams that are sun-bleached, water-damaged, dirty, scratched, missing corners, partially obscured by signage or posters, or hung at angles that make reading difficult.

The most common version: a diagram mounted near a window has faded to the point that the exit routes are barely visible. The diagram was technically correct when installed but is now functionally illegible.

Fix: substrate matters. Print onto UV-resistant material and mount in a frame with an anti-glare cover if direct sunlight is an issue (no glass or acrylic where open food is handled). Inspect each diagram visually at least annually and replace immediately if faded or damaged. 5 signs your evacuation diagrams need updating covers the warning patterns.

10. The assembly area shown no longer exists or is inaccessible

Assembly areas drift over time. The original assembly area was a section of car park; it has since been developed into an extension. The original assembly area was a grassed median; it has been re-landscaped into a planted garden bed. The original assembly area was a public footpath that has since been gated off.

When the diagram shows an assembly area that no longer functions as one, inspectors treat this as a serious failure because evacuating occupants may follow the diagram to a dead end during an actual emergency.

Fix: walk to the assembly area shown on each diagram and confirm it is still: accessible from all exits shown, large enough for the maximum building occupancy, free of vehicle conflict, and reachable without crossing dangerous infrastructure. If anything has changed, re-issue the diagram with the new assembly area and update the emergency plan accordingly. Emergency assembly areas: requirements and best practices covers the criteria.

11. The diagram is mounted on a fire door

Fire doors are required to be self-closing and to seal against smoke under their own weight or a closer. Anything mounted on the door (signage, posters, frames) can prevent the door from closing fully, compromising the smoke seal. The sign, its frame and the screws, glue or tape that hold it can also reduce the door's fire resistance. FPA Australia's Information Bulletin IB-11 warns that fitting a diagram to a fire or smoke door may contravene the Building Code of Australia and the fire door standard (AS 1905.1) unless the installation has been tested or a formal opinion obtained, and recommends against it.

A common failure: a building has a fire door at the entrance to a fire stair, and the diagram has been mounted on the door itself because the adjacent wall was busy with other signage. The mounting hardware (often a wooden frame or rigid acrylic) prevents the door from sealing.

Fix: never mount on fire doors. Use the adjacent wall, even if it requires moving other signage. If wall space is genuinely constrained, mount on a freestanding sign next to the fire door rather than on the door itself.

12. Missing diagrams at required locations

AS 3745:2010 has no fixed list of locations. Clause 3.5.2 requires diagrams to be displayed where occupants and visitors can see them, and makes the facility's Emergency Planning Committee responsible for deciding how many there are and where they go. In practice the set covers the main entrances and exits, the fire stair entry and lift lobby on each level, and any other point where people choose a direction on the way out.

In-room diagrams come from state rules. Queensland's Building Fire Safety Regulation 2008 (s 48) requires an evacuation sign in each accommodation unit, such as a hotel room or a holiday apartment. The NSW Short-term Rental Accommodation Fire Safety Standard (s 5.5) requires a diagram on or next to the entry door, and in each bedroom, of an apartment let as a short-term rental.

The two most common omissions: fire stair entries (the inspector finds a fire stair with no diagram on its entry level) and lift lobbies on upper floors (the building owner installed diagrams on the ground-floor lift lobby but not on the 2nd, 3rd, 4th floor lobbies).

Fix: produce a diagram-location schedule before commissioning, listing every location across every floor, and have the Emergency Planning Committee sign it off so the count is a decision, not a guess. For a typical 5-storey commercial building, the count is usually around 1 diagram per floor per stair, plus 1 per floor per lift lobby, plus 1 per major entrance, totalling 15 to 25 diagrams. Under-commissioning is a frequent cost-cutting failure that gets exposed at inspection time. Evacuation diagrams for high-rise buildings covers the location count for taller buildings.

Audit-window readiness checklist

If you know an inspection is coming (NSW AFSS renewal, a council compliance audit, a fire authority follow-up), the 1-day walk-through below catches most of the 12 failures above before an inspector does.

  • Walk every floor and identify every diagram mount location. Confirm the count matches the location schedule in the emergency plan (usually every fire stair entry, every lift lobby, every main entry, plus any other location relevant to evacuation).
  • At each diagram, stand directly in front of it and verify the "You Are Here" marker matches the actual mount location.
  • Verify the orientation. The "up" direction on the diagram should match the direction you would walk if you stepped forward from the diagram.
  • Measure the mount height against item 4: bottom edge no lower than 1,200 mm, or top edge no higher than 1,600 mm. A diagram that passes neither test, or one hung up near the ceiling or over a doorway, needs to be re-mounted.
  • Verify the date is on the diagram and is no older than 5 years. If the building has been renovated since the date, the diagram needs re-issue regardless of date.
  • Confirm the diagram size is correct for your element set: A3 if any optional element is shown (emergency numbers included), A4 only when the diagram carries the mandatory elements alone.
  • Verify each mandatory element is present (floor plan, "You Are Here," exits and green paths of travel, exit signs, fire equipment, manual and emergency call points, fire indicator panel, communications equipment such as warden intercommunication points where installed, assembly area, building name and address, validity date, legend). Emergency contact numbers are optional; if a diagram shows them, it must be A3.
  • Spot-check 3 fire equipment locations from the diagram against the actual building. Are the extinguishers and hose reels in the locations shown?
  • Walk to the assembly area shown. Is it accessible, sized for the building occupancy, and free of obstruction?
  • Verify legibility. Stand 1 m from each diagram and confirm exit routes, fire equipment, and any contact numbers shown are readable. Faded or damaged diagrams need to be replaced before the audit.
  • Confirm no diagram is mounted on a fire door.
  • Confirm any contact numbers shown on the diagrams are still current (the building manager, the fire warden, the after-hours emergency contact).

When to engage a supplier for re-issue rather than touch-ups

If your walk-through surfaces more than 3 of the 12 failures, the cost-effective path is a full re-issue from a fresh master file, not patchwork edits to the existing artwork. Patchwork edits (updating one element, re-printing one location, fixing one "You Are Here") rarely save money once you account for the design time, the re-print, and the re-mount.

A full re-issue from a current floor plan, with all mount locations rendered to spec, is usually cheaper than 4 to 5 individual patches. It also resets the set on a fresh master file for the next 5-year cycle, and it is the natural moment to get the master file release terms in writing, which protects against the supplier-lock-in problem covered in the supplier-switch guide.

Get inspection-ready diagrams

EvacPath produces AS 3745:2010-compliant evacuation diagrams across Australia, with every mount location rendered to spec, every mandatory element verified, and a dated, print-ready PDF delivered for each location. Pricing starts at A$70 per diagram and is published on the pricing page.

For audit-window timing (you have a fire safety inspection or AFSS renewal coming up and you want diagrams in hand before it lands): turnaround is typically 3 to 5 business days from receipt of a floor plan, with a same-day quote on the get-started page. Recent engagements are listed on the case studies page.

For inspection context beyond diagrams, the companion post what happens during a fire safety inspection covers the rest of what fire authority inspectors check, including fire detection, alarm systems, exit routes, fire doors, and emergency plan documentation.